 1W DC-DC Unregulated Dual Output Converter
Features :
3000VDC I/O isolation Internal SMD technology Protection: Short circuit Cooling by free air convection Non-conductive plastic case SMD package styles 100% full load burn-in test Low cost / High reliability Approved: UL / CUL 1 year warranty
DET01
series
SPECIFICATION
ORDER NO. DC OUTPUT VOLTAGE OUTPUT CURRENT RANGE EFFICIENCY RATED POWER OUTPUT DET01L-05 5V 100mA 72% 1W 71% DET01M-05 DET01L-09 9V 56mA 75% 73% DET01M-09 DET01L-12 12V 42mA 78% 74% DET01M-12 DET01L-15 15V 33mA 79% 75% DET01M-15
RIPPLE & NOISE (max.) Note.2 100mVp-p LINE REGULATION Note.3 1.2% for 1% input variation LOAD REGULATION Note.4 8.0% VOLTAGE TOLERANCE VOLTAGE RANGE NORMAL VOLTAGE 8.0% SWITCHING FREQUENCY(Typ.) 100KHz 4.5 ~ 5.5V 5V Full load 280mA No load 29mA Momentary Protection type : Broken Momentary Protection type : Broken -40 ~ +85 -40 ~ +105 (Refer to output load derating curve) , 10 ~ 95% RH 20% ~ 90% RH non-condensing 0.03% / (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes UL60950-1, CSA C22.2 I/P-O/P:3KVDC I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH 10.8 ~ 13.2V 12V 122mA 18mA 4.5 ~ 5.5V 5V 280mA 29mA 10.8 ~ 13.2V 12V 122mA 18mA 4.5 ~ 5.5V 5V 280mA 29mA 10.8 ~ 13.2V 12V 122mA 18mA 4.5 ~ 5.5V 5V 280mA 29mA 10.8 ~ 13.2V 12V 122mA 29mA
INPUT
INPUT CURRENT PROTECTION OVERLOAD
Fuse recommended
PROTECTION SHORT CIRCUIT WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE MTBF OTHERS DIMENSION WEIGHT
500khrs min. MIL-HDBK-217F(25 ) 15.24*7.5*6.0mm or 0.60"*0.30"*0.24" inch (L*W*H) 1.7g
Mechanical Specification
15.24
12 11 1 0 8 7
Unit: mm (inch)
Pin Configuration
Pin No.
1 2 3 5 6 7 8 10 11 12
Derating Curve
Output
-Vin +Vin NC COM -Vout NC +Vout NC NC NC
100
LOAD (%)
80
11.2 MAX
7.50
6.25
TOP VIEW
1 2 3 5 6
6.00
2.54
0 .2 5
2.54
0.5
4 .1 3
-40
0
25
50 70 85
100
Ta (
)
NOTE
1.All parameters are specified at normal input, rated load, 25 70% RH. Ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Line regulation is measured from low line to high line at rated load. 4.Load regulation is measured from 20% to 100% rated load.
File Name: DET01-SPEC 2008-05-08


▲Up To Search▲   

 
Price & Availability of DET01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X